CHANGES IN BIOIMPEDANCE DEPENDING ON CONDITIONS
The aim of the paper is to present results of our ongoing research focused on the influence of measurement condition change on body composition measurements. The performed measurements showed certain influence which must be verified by repeated experiments. These changes can lead to important conclusion and further standardization.
Keywords:
Bioimpedance, Body composition, BIA, Body fat
Autoři: J. Hlubik 1; P. Hlubik 2; L. Lhotská 1
Působiště autorů: Gerstner Laboratory, Faculty of Electrical Engineering, Czech Technical University in Prague Czech Republic 1; Faculty of Military Health Sciences Hradec Králové, University of Defense, Czech Republic 2
Vyšlo v časopise: Lékař a technika - Clinician and Technology No. 2, 2012, 42, 69-72
Kategorie: Conference YBERC 2012
Souhrn
The aim of the paper is to present results of our ongoing research focused on the influence of measurement condition change on body composition measurements. The performed measurements showed certain influence which must be verified by repeated experiments. These changes can lead to important conclusion and further standardization.
Keywords:
Bioimpedance, Body composition, BIA, Body fat
Zdroje
[1] Dympna Gallagher, Steven B Heymsfield, Moonseong Heo, Susan A Jebb, Peter R Murgatroyd, and Yoichi Sakamoto Healthy percentage body fat ranges: an approach for developing guidelines based on body mass index1 Am J Clin Nutr 2000;72 : 694–701
[2] Linda Paniagua, Vitool Lohsoonthorna, Somrat Lertmaharit,Wiroj Jiamjarasrangsi, Michelle A. Williams(2008) Comparison of waist circumference, body mass index, percent body fat and other measure of adiposity in identifying cardiovascular disease risks among Thai adults. Obesity Research & Clinical Practice (2008) 2, 215—223.
[3] Nayeli Macias, Heliodoro Alemán-Mateo, Julián Esparza-Romero and Mauro E Valencia(2007) Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design. Nutrition Journal 2007, 6 : 18 doi:10.1186/1475-2891-6-18
[4] Kentaro Shoji, Kazuhisa Maedaa, Tadashi Nakamura, Tohru Funahashi, Yuji Matsuzawa, Iichiro Shimomura(2008) Measurement of visceral fat by abdominal bioelectrical impedance analysis is beneficial in medical checkup. Obesity Research & Clinical Practice (2008) 2, 269—275
Štítky
Biomedicína
Článok vyšiel v časopiseLékař a technika
2012 Číslo 2-
Všetky články tohto čísla
- EYE TRACKING PRINCIPLES AND I4TRACKING® DEVICE
- MODELING OF CIRCULATION DYNAMICS WITH ACAUSAL MODELING TOOLS
- Methodology of thermographic atlas of the human body
- INDUCTION SENSORS FOR MEASUREMENT OF VIBRATION PARAMETERS OF ULTRASONIC SURGICAL WAVEGUIDES
- Linear Modelling of Cardiovascular Parameter Dynamics during Stress-Test in Horses
- MONITORING OF BREATHING BY BIOACOUSTIC METHOD
- Editorial
- APPLICATION OF TIME DOMAIN REFLECTOMETRY FOR CHARACTERIZATION OF HUMAN SKIN
- REAL-TIME PROCESSING OF MULTICHANNEL ECG SIGNALS USING GRAPHIC PROCESSING UNITS
- MATLAB AND ITS USE FOR PROCESSING OF THERMOGRAMS
- IDENTIFICATION OF MAGNETIC NANOPARTICLES BY SQUID BIOSUSCEPTOMETRIC SYSTEM
- EXPORT OF INFORMATION FROM MEDICAL RECORDS INTO DATABASE
- WIRELLES PROBE FOR HUMAN BODY BIOSIGNALS
- Written test on biophysics and medical biophysics at medical faculty, comenius university in Bratislava - a continuous check during two academic years
- The Fifth Biomedical Engineering Conference of Young Biomedical Engineers and Researchers
- VALUATION METHODOLOGY FOR MEDICAL DEVICES
- SETTING EMG STIMULATION PARAMETERS BY MICROCONTROLLER MSP430
- SOFTWARE PACKAGE FOR ELECTROPHYSIOLOGICAL MODELING OF NEURONAL AND CARDIAC EXCITABLE CELLS
- VENTILATOR CIRCUIT MODEL FOR OPTIMIZATION OF HIGH-FREQUENCY OSCILLATORY VENTILATION
- REHABILITATION OF PATIENTS USING ACCELEROMETERS: FIRST EXPERIMENTS
- CHANGES IN BIOIMPEDANCE DEPENDING ON CONDITIONS
- NONINVASIVE SYSTEM FOR LOCALIZATION OF SMALL REPOLARIZATION CHANGES IN THE HEART
- THE STRUCTURAL DESIGN AND USE OF HIGHER FORMS OF CONTROL IN REHABILITATION DEVICES
- MECHANICAL MODEL OF THE CARDIOVASCULAR SYSTEM: DETERMINATION OF CARDIAC OUTPUT BY DYE DILUTION
- AUTOMATIC SEGMENTATION OF PHONEMES DURING THE FAST REPETITION OF (/PA/-/TA/-/KA/) SYLLABLES IN A SPEECH AFFECTED BY HYPOKINETIC DYSARTHRIA
- A PHONEME CLASSIFICATION USING PCA AND SSOM METHODS FOR A CHILDREN DISORDER SPEECH ANALYSIS
- THE REAL-TIME VIZUALIZATION OF PNEUMOGRAM SIGNALS
- USE OF CORRELATION ANALYSIS FOR ONSET EPILEPTIC SEIZURE DETECTION
- FEEDBACK VISUALIZATION INFLUENCE ON A BRAIN-COMPUTER INTERFACE PERFORMANCE
- Lékař a technika
- Archív čísel
- Aktuálne číslo
- Informácie o časopise
Najčítanejšie v tomto čísle- MECHANICAL MODEL OF THE CARDIOVASCULAR SYSTEM: DETERMINATION OF CARDIAC OUTPUT BY DYE DILUTION
- MATLAB AND ITS USE FOR PROCESSING OF THERMOGRAMS
- The Fifth Biomedical Engineering Conference of Young Biomedical Engineers and Researchers
- VALUATION METHODOLOGY FOR MEDICAL DEVICES
Prihlásenie#ADS_BOTTOM_SCRIPTS#Zabudnuté hesloZadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.
- Časopisy