Inhalatory Application of Nitric Oxide (iNO) Using a SimpleMethod West ®


Inhalatory Application of Nitric Oxide (iNO) Using a SimpleMethod West ®

The light of the smoking cigarette was connected into an inspiratory line about 30 cm far from an electroche-mical sensor for detection of inhaled nitric oxide (iNO, SensorNOx, Sensormedics, Yorba Linda, CA). In in vitroexperiments antiadiabatic model of neonatal lung was used and two types of high frequency oscillators (Sensor-medics 3100A and Infant Star). Four ventilator settings were tested for measurement of iNO and iNO2 in theventilator circuits with continuous back up flow 6 - 10 L/min. Concentrations of iNO in the range 10 - 83 ppm anda zero concentration of NO2 was detected 30 min after starting the experiments. These concentrations are in therange used frequently in clinical practice.

Klíčová slova:
iNO, high frequency oscillation, children, cigarette smoke


Inhalační aplikace kysličníku dusnatého (NO) pomocí jednoduché metody West ®

Oheň zapálené cigarety byl spojen s inspirační linkou asi 30 cm vzdálené od elektrochemického čidla pro detekcivdechovaného kysličníku dusnatého (iNO, Sensor NOx, Sensormedics, Yorba Linda, CA). V pokusech in vitro bylopoužito antiadiabetického modelu neonatálních plic a dva typy vysokofrekvenčních oscilátorů (Sensormedics 3100a Infant Star). Čtyři uspořádání ventilátorů byla zkoumána pro stanovení iNO a iNO2 v okruzích ventilátorů sezpětným tokem 6 - 10 L/min. Koncentrace iNO v rozmezí 10 - 83 ppm a nulové koncentrace NO2 byly zjištěny 30minut po zahájení pokusů. Tyto koncentrace jsou v rozmezí, které se často používá v klinické praxi.

Key words:
iNO, vysokofrekvenční oscilace, děti, cigaretový kouř


Autoři: R. Nekvasil *;  M. Fedora;  M. Klimovič;  M. Šeda;  P. Dominik
Působiště autorů: Paediatric Intensive Care Unit
Vyšlo v časopise: Čes-slov Pediat 2000; (4): 236-237.
Kategorie: Články

Souhrn

The light of the smoking cigarette was connected into an inspiratory line about 30 cm far from an electroche-mical sensor for detection of inhaled nitric oxide (iNO, SensorNOx, Sensormedics, Yorba Linda, CA). In in vitroexperiments antiadiabatic model of neonatal lung was used and two types of high frequency oscillators (Sensor-medics 3100A and Infant Star). Four ventilator settings were tested for measurement of iNO and iNO2 in theventilator circuits with continuous back up flow 6 - 10 L/min. Concentrations of iNO in the range 10 - 83 ppm anda zero concentration of NO2 was detected 30 min after starting the experiments. These concentrations are in therange used frequently in clinical practice.

Klíčová slova:
iNO, high frequency oscillation, children, cigarette smoke

Plné znenie tohto článku nie je v digitalizovanej podobe.
V prípade záujmu kontaktujte NTO ČLS JEP, ktoré vám môže poskytnúť sken časopisu.

Štítky
Neonatológia Pediatria Praktické lekárstvo pre deti a dorast

Článok vyšiel v časopise

Česko-slovenská pediatrie


2000 Číslo 4
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Kurzy

Zvýšte si kvalifikáciu online z pohodlia domova

Eozinofilní granulomatóza s polyangiitidou
nový kurz
Autori: doc. MUDr. Martina Doubková, Ph.D.

Všetky kurzy
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#